SET_DUT_RELAY
L5710 Tester - 指令 - SET_DUT_RELAY
The SET_DUT_RELAY instruction is used to close/open the utility relays.
*Syntax :
SET_DUT RELAY( Dut_Relay_Group)
*Arguments :
Dut_Relay_Group:any dut relay group name which had been defined by user in the test program. the dut relay group is defined in the plan file (main program).
*Comment:
SET_DUT_RELAY will open/close the utility relays which are defined in the DUT_RELAY_GROUP.
Every SET_DUT_RELAY instruction is independent. It means that the instruction will not keep the relay state for the last SET_DUT_RELAY.
*Example :
DUT_RELAY_GROUP;
Dut_G1=(0, 1, 2);
Dut_G2=(1,2, 15);
Null_G=();
→no utility relay in the group
END DUT_RELAY_GROUP;
……
……
SET_DUT_RELAY(Dut_G1);
→utility relay 0, 1, 2 are closed
SET_DUT_RELAY(Dut_G2);
→ utility relay 1, 2, 15 are closed, relay 0 is opened
……
SET_DUT_RELAY(Null_G);
→ all utility relays are opened