DPS_FI, DPS_FV
L5710 Tester - 指令 - DPS_FI, DPS_FV
These instructions force a specified value to the DPS.
*Syntax:
DPS_FI( DPS_No, Force_Value, VI_Range)
DPS_FV(DPS_No, Force_Value, VI_Range)
*Arguments :
DPS_No:the DPS which is selected to force value. The actual DPS number is from 1 to 4.
Force Value:value + unit (A, mA, UA, V, mV). which range depend on VI Range.
VI_Range:There are 4 V_Range and 7 I_Range defined as following
E1:+/- 2V
E2:+/- 4V
E3: +/- 8V
E4:+/-10V
I1:+/- 1uA
12:+/- 10uA
13:+/- 100uA
14:+/- 1mA
I5:+/- 10mA
16:+/- 100mA
17:+/- 1A
*Comment:
The instruction will select the VI_Range, set the value, connect the specified DPS relay, delay a period of time (which is not defined by the user) and force the specified value to the selected DPS.
For preventing hot switching, force the value to zero before the change of the VI_Range.
*Example:
DPS_FV(DPS1, 2.400V, V216);
DPS_FI(DPS2, -100uA, V214);
#關鍵字 L5710 Tester - 指令 - DPS_FI, DPS_FV
■ 延伸閱讀 :L5710 指令說明 & 其它
留言列表