DPS_MI, DPS_MV

L5710 Tester - 指令 - DPS_MI, DPS_MV


These instructions measure a value from the DPS and judge the pass/fail.

 

*Syntax :

DPS_MI(DPS No, Low_Limit, High_Limit, Test_Flag)

DPS_MV(DPS_No, Low_Limit, High_Limit, Test_Flag)

 

*Arguments :

DPS No: the DPS which is selected to force value. The actual DPS number is from 1 to 4.

Low Limit: value + unit (A, mA, uA, V, mV).

High Limit: value + unit (A, mA, uA, V, mV).

Test_Flag:

"ON" care about the pass/fail result and fail-stop.

"OFF" don't care about the pass/fail result and fail not to stops.

 

*Comment:

The instructions measure the value and judge if the result is between Low_Limit and High_Limit. If it is true, the test result is PASS.

Otherwise, the test result is FAIL. The VI_Range for the two instructions are the same as the DPS_FV or DPS_FI which is defined before the two instructions.

 

*Example :

DPS_FV(DPS1, 2.400V, V216);

……

DPS_MV(DPS2, -2.0V, -200mV, OFF);

DPS_MI(DPS1, -5uA, 5uA, ON);