close

DPS_FI, DPS_FV

L5710 Tester - 指令 - DPS_FI, DPS_FV


These instructions force a specified value to the DPS.

 

*Syntax:

DPS_FI( DPS_No, Force_Value, VI_Range)

DPS_FV(DPS_No, Force_Value, VI_Range)

 

 *Arguments :

DPS_No:the DPS which is selected to force value. The actual DPS number is from 1 to 4.

Force Value:value + unit (A, mA, UA, V, mV). which range depend on VI Range.

VI_Range:There are 4 V_Range and 7 I_Range defined as following

E1:+/- 2V

E2:+/- 4V

E3: +/- 8V

E4:+/-10V

 

 

I1:+/- 1uA

12:+/- 10uA

13:+/- 100uA

14:+/- 1mA

I5:+/- 10mA

16:+/- 100mA

17:+/- 1A

 

*Comment:

The instruction will select the VI_Range, set the value, connect the specified DPS relay, delay a period of time (which is not defined by the user) and force the specified value to the selected DPS.

For preventing hot switching, force the value to zero before the change of the VI_Range.

 

*Example:

DPS_FV(DPS1, 2.400V, V216);

DPS_FI(DPS2, -100uA, V214);


#關鍵字 L5710 Tester - 指令 - DPS_FI, DPS_FV

 

 


■ 延伸閱讀 L5710 指令說明 & 其它


arrow
arrow
    全站熱搜

    News123 發表在 痞客邦 留言(0) 人氣()