close

SET_BURST_FLAG

L5710 Tester - 指令 - SET_BURST_FLAG


The SET BURST_FLAG instruction is used to set the BURST_PATTERN condition..

 

*Syntax :

SET_BURST_FLAG( Parallel_Burst_Flag, AC_Ignore_Flag)

 

*Arguments :

Parallel_Burst_Flag

"ON" parallel burst pattern simultaneously when more than one dut is selected.

"OFF" burst pattern one dut by one dut in spite of one or more dut is selected.

AC_Ignore_Flag

"ON" the burst pattern doesn't terminate when encountering a fail and doesn't care about the fail.

"OFF" burst pattern terminates when encountering a fail and judge to fail.

 

*Comment:

L5710 provides a single, dual, four duts test. When selecting more than one dut test, the user can choose parallel burst or not. But when using MATCH/ SUB MATCH microinstruction, the user must set Parallel_Burst_Flag to OFF. If the user wants to debug a pattern, AC_Ignore_Flag is always set to ON. In a go-no-go test, AC_Ignore_Flag is set to OFF.

 

*Example: 

……

SET_BURST_FLAG(ON, OFF);

BURST_PATTERN(Example, ST, SP);

……