DPS_FVMI, DPS_FIMV

L5710 Tester - 指令 - DPS_FVMI, DPS_FIMV


These instructions force a specified value to DPS. After waiting a delay time, measure a value from the DPS and judge the pass/fail.

 

*Syntax :

DPS FVMI( DPS_No, Force_Value, VI_Range, Low_Limit, High Limit, Delay Time, Test_Flag)

DPS_FIMV(DPS_No, Force_Value, VI Range, Low_Limit, High Limit, Delay Time, Test_Flag)

 

*Arguments :

DPS_No: the DPS which is selected to force value. The actual DPS number 1to 4.

Force Value: value + unit (A, mA, uA, V, mV). which range depends on VI_Range

VI_Range: There are 4 V_Range and 71_Range defined as following

El:+/-2V

E2:+/-4V

E3:+/-8V

 

E4:+/-10V

I1:+/- 1uA

I2:+/- 10uA

I3:+/- 100uA

I4:+/- 1mA

I5:+/- 10mA

I6:+/- 100mA

I7:+/- 1A

 

 

Low_Limit:value + unit (A, mA, uA, V, mV).

High Limit: value + unit ( A, mA, UA, V, mV).

Delay Time: value + unit (s, ms, us).

Test_Flag

"ON" care the pass/fail result and fail stop.

"OFF" don't care the pass/fail result and fail not stop.

 

*Comment:

The instructions will select the VI_Range, set the value, connect the specified DPS relay, delay a period of time (which is not defined by the user) and force the specified value to the selected DPS. After waiting a delay time (which is defined by the user) measure the value from DPS and judge if the result is between Low_Limit and High_Limit. If it is true, the test result is PASS. Otherwise, the test result is FAIL.

For preventing hot switching, force the value to zero before the change of the VI_Range.

The VI_Range of the measured value is the same as the force value.

 

*Example :

DPS_FIMV(DPS1, -100.000uA, V113, -1.200V, -200.000mV,3.000ms, ON);